Characteristics
The pre-assembled manifold station consists of a manifold cabinet, a heating circuit manifold and a heat meter installation kit. In the following, it is possible to choose between different versions in order to adapt the station to your individual requirements.
- Manifold cabinet
TT‑VS‑110T / 80T - flush-mounted, height: 700‑880 mm, depth: 100‑198 mm / 80‑120 mm
TT‑VS‑A - surface-mounted, height: 564 mm, depth: 125 mm - Stainless steel manifold
VA-FBif with flow meters 0‑5,0 l/min, can be shut-off
DYNA-if with flow indicator 0‑5,0 l/min - Heat meter installation kit TT‑WMZw 1" with heat meter up to 1,5 Qn.
Return consisting of 1x ball valve G1" M10, 1x fitting piece for meter 110 mm, 1x screwing part.
Supply consisting of 1x ball valve G1" M10, 2x fill and drain valve G½", 2x manifold end plug G1", 2x vent valve G½" - Connection variant right or left possible
| ORDER NO. | |
|---|---|
| 37.02.204 - 37.15.204 | TT‑WMZw 1" for 2‑15 circuits, flush-mounted cabinet TT‑VS‑110T, stainless steel manifold VA‑FBif |
| 38.02.204 - 38.15.204 | TT‑WMZw 1" for 2‑15 circuits, flush-mounted cabinet TT‑VS‑110T, stainless steel manifold DYNA‑if |
| 37.02.208 - 37.15.208 | TT‑WMZw 1" for 2‑15 circuits, flush-mounted cabinet TT‑VS‑80T, stainless steel manifold VA‑FBif |
| 38.02.208 - 38.15.208 | TT‑WMZw 1" for 2‑15 circuits, flush-mounted cabinet TT‑VS‑80T, stainless steel manifold DYNA‑if |
| 37.02.212 - 37.13.212 | TT‑WMZw 1" for 2‑13 circuits, flush-mounted cabinet TT‑VS‑A, stainless steel manifold VA‑FBif |
| 38.02.212 - 38.13.212 | TT‑WMZw 1" for 2‑13 circuits, flush-mounted cabinet TT‑VS‑A, stainless steel manifold DYNA‑if |