Fresh water station FW-D 40

FRESH WATER STATION

FW-D 40

  • for central drinking water heating using the flow principle

Dimensions (WxHxD): 480 x 675 x 240 mm

Primary
Buffer tank
Secondary
Drinking water
Pressure stage: PN 6 PN 10
Max. temperature: 110 °C 75 °C
Connection dimensions: DN 25 DN 20
Threads: 1" female threads 1" male threads

Our FW-D 40 fresh water station heats up the drinking water centrally and it is distributed to the tapping points
via the hot water pipe. A buffer tank is necessary so that a sufficient heating water volume flow is provided for heating
up the drinking water. The drinking hot water is only heated on demand „Just in Time“. There is no storage of drinking
hot water!

 

Performance data: PI1* PI2*
HW performance: 90 KW 100 KW
Mass flow primary: 1745 kg/h 1769 kg/h
Supply temperature: 60 °C 70 °C
Return temperature: 16 °C 22 °C
CW / HW temperature: 10 °C / 45 °C 10 °C / 60 °C
Tap performance: 36 l/min 28 l/min

Attention! Standard operation is guaranteed at 50-75°C, if necessary install a pre-mixer
*PI1 = Performance indicator 1 (at set hot water temperature 45°C, at primary supply temperature 60°C, at cold water temperature 10°C)
*PI2 = Performance indicator 1 (at set hot water temperature 45°C, at primary supply temperature 60°C, at cold water temperature 10°C)